Add to Cart
A4VSO355EO2/22R-VPB13N00 A4VSO355EO2/22R-PPB13N00 A4VSO355EO1/22R-VPB25N00
A4VSO355EO1/22R-VZB13N00 A4VSO355EO1/22R-PZB13N00 Industrial high-pressure A4VSO355 Rexroth German hydraulic pump
Working principle: | Hydraulic Piston Pump | purpose: | hydraulic system |
series: | Single level | material: | cast iron |
scope of application: | construction machinery | Applicable Medium: | Hydraulic oil-water ethylene glycol |
Applicable temperature (℃)): | 30-90 | Nominal pressure (MPa): | 32MPA |
Is there any stock available: | YES | Installation form: | Flange coupling |
Rated flow rate: | 12 | Specification and model: | A4VSO355EO2/22R-VPB13N00 A4VSO355EO2/22R-PPB13N00 A4VSO355EO1/22R-VPB25N00 A4VSO355EO1/22R-VZB13N00 A4VSO355EO1/22R-PZB13N00 |
brand: | Rexroth | package: | Wooden crate |
whatsapp: | +85267220981 | email: | Yli97584@gmail.com |
R902516347 | AA4VSO355DFEH/30R-FZB25U99 |
R902466583 | AA4VSO355DFR/30R-PPB13K35 |
R902431979 | AA4VSO355DFR/30R-PPB13K37 |
R902420478 | AA4VSO355DFR/30R-PPB13K77 |
R902479529 | AA4VSO355DFR/30R-PPB25I20 |
R902446645 | AA4VSO355DFR/30R-PPB25K24 |
R910999748 | AA4VSO355DFR/30R-PPB25N00 |
R902493053 | AA4VSO355DFR/30R-PPB25UB7 |
R910995920 | AA4VSO355DFR/30R-PZB13K77 |
R910995918 | AA4VSO355DFR/30R-PZB13N00 |
R902429996 | AA4VSO355DFR/30R-VZB13N00 |
R902531120 | AA4VSO355DFR/30R-FPB13N00 |
R902461782 | AA4VSO355DFR/30R-PPB13N00 |
R902422218 | AA4VSO355DFR1/30R-PPB13N00 |
R902563102 | AA4VSO355DFR1/30R-PPB13N00-SO318 |
R902563003 | AA4VSO355DFR1/30R-PPB25L70 |
R902535707 | AA4VSO355DFR1/30R-PZB13K34-S2143 |
R902484095 | AA4VSO355DFR1/30R-VZB25U99 |
R902466806 | AA4VSO355DP/30R-PPB13K07-SO318 |
R902403263 | AA4VSO355DP/30R-PPB13N00 |
R902488362 | AA4VSO355DP/30R-PPB13N00-S1231 |
R902488245 | AA4VSO355DP/30R-PPB13N00-SO19 |
R902417215 | AA4VSO355DP/30R-PPB13N00-SO646 |
R902420476 | AA4VSO355DP/30R-PPB13N00-SO890 |
R902558179 | AA4VSO355DP/30R-PPB13N00-SO959 |
R902562671 | AA4VSO355DP/30R-PPB13N00CSO890 |
R902562670 | AA4VSO355DP/30R-PPB25N00 |
R902435744 | AA4VSO355DP/30R-PPB25N00-S1559 |
R902465626 | AA4VSO355DP/30R-PPB25N00-SO527 |
R902562212 | AA4VSO355DP/30R-PPB25U07 |
R902455117 | AA4VSO355DP/30R-PZB13K77 |
R902547376 | AA4VSO355DP/30R-PZB25U33 |
R902547392 | AA4VSO355DP/30R-PZB25U34 |
R902455900 | AA4VSO355DP/30R-PZB25U35 |
R902454931 | AA4VSO355DP/30R-PZB25U77 |
R | |
902455937 | AA4VSO355DP/30R-PZB25U77 |
R902569298 | AA4VSO355DP/30R-PZB25U83 |
R902545121 | AA4VSO355DP/30R-VZB25U04-SO527 |
R902491498 | AA4VSO355DP/30R-VZB25U77 |
R902451990 | AA4VSO355DR/30R-FPB13K77 |
R902479386 | AA4VSO355DR/30R-FPB13N00 |
R902548456 | AA4VSO355DR/30R-FPB13N00E |
R902436713 | AA4VSO355DR/30R-PPB13K02 |
R902411077 | AA4VSO355DR/30R-PPB13K31 |
R902405609 | AA4VSO355DR/30R-PPB13N00 |
R902408289 | AA4VSO355DR/30R-PPB13N00-SO410 |
R902470643 | AA4VSO355DR/30R-PPB13N00E |
R902411960 | AA4VSO355DR/30R-PPB25K31 |
R902417937 | AA4VSO355DR/30R-PPB25K77 |
R902448295 | AA4VSO355DR/30R-PPB25K77-SO318 |
R902544159 | AA4VSO355DR/30R-PPB25U33 |
R902512543 | AA4VSO355DR/30R-PPB25U77 |
R902485961 | AA4VSO355DR/30R-PZB13N00 |
R902417938 | AA4VSO355DR/30R-PZB25N00 |
R902538882 | AA4VSO355DR/30R-PZB25U31 |
R902486475 | AA4VSO355DR/30R-PZB25U33 |
R902437177 | AA4VSO355DR/30R-VPB13K02 |
R902412724 | AA4VSO355DR/30R-VPB13N00 |
R902517881 | AA4VSO355DR/30R-VPB25H00 |
R902570238 | AA4VSO355DR/30R-VPB25U34 |
R902541638 | AA4VSO355DR/30R-VPB25UB3 |
R902423429 | AA4VSO355DR/30R-VZB13N00 |
R902532203 | AA4VSO355DR/30R-VZB25N00 |
R902560381 | AA4VSO355DR/30R-PPB13N00-SO860 |
R902473502 | AA4VSO355DRG/30R-PZB25U77 |
R902535181 | AA4VSO355DRG/30R-VZB25U34 |
R902479194 | AA4VSO355DRG/30R-VZB25U77 |
R902546955 | AA4VSO355DRG/30R-VZB25UB7 |
R902486364 | AA4VSO355DRG/30R-FPB13N00 |
R902463881 | AA4VSO355DRG/30R-PPB13H00 |
R902419033 | AA4VSO355DRG/30R-PPB13K07 |
R902452604 | AA4VSO355DRG/30R-PPB13K77 |
R902408078 | AA4VSO355DRG/30R-PPB13N00 |
R902412011 | AA4VSO355DRG/30R-PPB13N00-S1051 |
R902563045 | AA4VSO355DRG/30R-PPB13N00-S1279 |
R902447102 | AA4VSO355DRG/30R-PPB13N00-SO527 |
R902411592 | AA4VSO355DRG/30R-PPB25N00 |
R902497936 | AA4VSO355DRG/30R-PPB25U35 |
R902452204 | AA4VSO355DRG/30R-PZB13K77 |
R902463930 | AA4VSO355DRG/30R-PZB13KB7 |
R902424461 | AA4VSO355DRG/30R-PZB13N00 |
R902541068 | AA4VSO355DRG/30R-PZB25N00 |
R902419264 | AA4VSO355DRG/30R-PZB25N00-SO580 |
R902405663 | AA4VSO355DRG/30R-VPB13N00 |
R902406619 | AA4VSO355DRG/30R-VPB13N00E |
R902406176 | AA4VSO355DRG/30R-VPB13N00E |
R902553845 | AA4VSO355DRG/30R-VPB25U99ESO171 |
R902543445 | AA4VSO355DRG/30R-VZB25N00 |
R902485052 | AA4VSO355DRG/30R-VZB25U07-SO91 |
R902540618 | AA4VSO355DRG/30R-VZB25U31-SO580 |
R902565577 | AA4VSO355DRG/30R-VZB25U35 |
R902518249 | AA4VSO355DRG/30R-VZB25U68-S1036 |
R902479392 | AA4VSO355DRG/30R-VZB25U77-SO91 |
R902448665 | AA4VSO355DRM/30R-PPB13N00-S1576 |
R902404356 | AA4VSO355EM1091/30R-PPB13N00-SO415 |
R902404896 | AA4VSO355EM3070/30R-VPB13N00 |
R902410667 | AA4VSO355EO2/30R-PPB13G30 |
R902418246 | AA4VSO355EO2/30R-PPB13K00-SO957 |
FAQ:
3. Operation & Fluid Management
Q5: What hydraulic oil should I use, and what is the optimal viscosity?
• Oil Types: Recommended fluids include mineral oils (RC 90220), environmentally friendly fluids (RC 90221), and HF fluids (HFA, HFB, HFC - check seal compatibility, typically FKM for HFD; RC 90223). Specify the fluid type when ordering.
• Viscosity Range: The optimal operating viscosity range (at operating temperature) is 16 to 36 mm²/s. Absolute limits are:
◦ Minimum: 10 mm²/s (short-term, max. case drain temp 90°C)
◦ Maximum: 1000 mm²/s (short-term, cold start).
• Selection: Select a viscosity grade (e.g., VG 46, VG 68) so that the viscosity at the operating temperature (typically tank temperature in open circuits) falls within the optimal range. Generally, opting for a higher viscosity grade is advised.
Q6: What are the fluid cleanliness requirements?
To ensure reliable operation and long service life, the oil cleanliness should be at least NAS 1638 Class 9 or ISO/DIS 4406 18/15.
Q7: Why does my pump get overheated?
Common causes for excessive heating include:
• Internal Leakage: Excessive internal leakage within the pump components converts hydraulic energy to heat.
• Mechanical Friction: Dry or semi-dry friction due to worn parts or inadequate lubrication generates heat.
• Fluid Friction: Inadequate tank capacity or cooling, causing the system to overheat.
• Clogged Return Line Filter: A blocked return filter creates high backpressure, leading to increased temperature.
• Low Oil Level: Insufficient oil in the reservoir reduces cooling capacity.