Add to Cart
4WRA6E20-1X/24NZ4/MR
4WRA6EA20-1X/24NJ/V
4WRA6E1-10-1X/24Z4/M
4WRA6E20-1X/24N9Z4/V
4WRA6E1-10-1X/24N9Z4/V Hydraulic valve German hydraulic proportional directional valve imported from Rexroth
| Processing & Customization | yes | type | proportional valve |
| material | cast steel | model | 4WRA6E20-1X/24NZ4/MR 4WRA6EA20-1X/24NJ/V 4WRA6E1-10-1X/24Z4/M 4WRA6E20-1X/24N9Z4/V 4WRA6E1-10-1X/24N9Z4/V |
| brand | REXROTH | Scope of Application | hydraulic system |
| Product Alias | Proportional directional valve | Applicable Medium | oil products |
| Applicable Temperature | Normal temperature (℃) ℃ | Nominal Pressure | Normal pressure (MPa) MPa |
| Nominal Diameter | 6-way diameter (mm) mm | Installation type | Threaded installation |
| Operating Temperature | room temperature | Type (channel location) | Straight through type |

| 0811404800 4WRPEH10C3B50L–2X/G24K0/A1M |
| 0811404801 4WRPEH10C3B100L–2X/G24K0/A1M |
| 0811404756 4WRPEH10C5B50L–2X/G24K0/A1M |
| 0811404757 4WRPEH10C5B100L–2X/G24K0/A1M |
| 0811404822 4WRPEH10C3B50P–2X/G24K0/A1M |
| 0811404823 4WRPEH10C3B100P–2X/G24K0/A1M |
| 0811404826 4WRPEH10C5B 50P–2X/G24K0/A1M |
| 0811404827 4WRPEH10C5B100P–2X/G24K0/A1M |
| 0811404819 4WRPEH10C3B 50L–2X/G24K0/F1M |
| 0811404817 4WRPEH10C3B100L–2X/G24K0/F1M |
| 0811404758 4WRPEH10C5B 50L–2X/G24K0/F1M |
| 0811404759 4WRPEH10C5B100L–2X/G24K0/F1M |
| 0811404802 4WRPEH10C4B 50L–2X/G24K0/A1M |
| 0811404820 4WRPEH10C4B100L–2X/G24K0/A1M |
| 0811404803 4WRPEH10C1B 50L–2X/G24K0/A1M |
| 0811404821 4WRPEH10C1B100L–2X/G24K0/A1M |
| 0811404824 4WRPEH10C4B 50P–2X/G24K0/A1M |
| 0811404825 4WRPEH10C4B100P–2X/G24K0/A1M |
| 0811404828 4WRPEH10C1B 50P–2X/G24K0/A1M |
| 0811404829 4WRPEH10C1B100P–2X/G24K0/A1M |
| 0811404760 4WRPEH10C4B 50L–2X/G24K0/F1M |
| 0811404761 4WRPEH10C4B100L–2X/G24K0/F1M |
| 0811404762 4WRPEH10C1B 50L–2X/G24K0/F1M |
| 0811404763 4WRPEH10C1B100L–2X/G24K0/F1M |
| 0811404764 4WRPEH10CB 50L–2X/G24K0/A1M |
| 0811404809 4WRPEH10CB100L–2X/G24K0/A1M |
| 0811404765 4WRPEH10CB 50L–2X/G24K0/F1M |
FAQ;
What are common troubleshooting issues?
Common problems and their potential causes include :
• Valve does not shift or responds slowly: Check solenoid coil for burnout or open circuit; check power supply voltage; check for contamination causing the spool to stick.
• Internal Leakage: Worn spool or seals, or contamination causing improper sealing .
• Valve sticking: Often due to inadequate fluid cleanliness, insufficient lubrication, or internal damage .
• Excessive noise: Can be caused by excessive vibration, voltage fluctuations, or issues with the solenoid .
• No function despite signal: Check the amplifier (for 4WRA), wiring, and connections between the control unit and the valve .
8. What maintenance is required?
• Regularly check the solenoid coils and valve spool for wear .
• Maintain fluid cleanliness to prevent contamination, which is a primary cause of valve failure. Ensure the filtration system is functioning properly .
• Periodically inspect electrical connections and seals.